Scope of Application and Precautions for Shanghai Yetuo Low Temperature Tank
release time:2023-02-07  |  Browse:2473

Scope of application of Shanghai Yetuo low-temperature tank

The Shanghai Yetuo low-temperature bath and low-temperature constant temperature bath are widely used in fields such as biotechnology, medicine, food, chemical engineering, metallurgy, chemical analysis, and petroleum. Provide users with a high-precision, controlled, and temperature uniform testing tool. It is an ideal low-temperature constant temperature bath for research institutes, universities, factory laboratories, and quality inspection departments. 

Main technical indicators

The technical parameters of Shanghai Yetuo low-temperature bath include: temperature control range, temperature control accuracy, bath volume, digital display resolution, pump flow rate, and working voltage. These parameters are the main basis for selecting a suitable low-temperature bath, among which the temperature control range and bath volume are the main selection parameters. The temperature control range generally includes different temperature ranges such as -5~100 ℃, -10~100 ℃, -20~100 ℃, -30~100 ℃, -40~100 ℃, -50~100 ℃, -60~100 ℃, etc. The temperature can be set freely within this range; The bath capacity generally ranges from 10L to 20L, 20L to 30L, or even more. These two parameters are the main considerations for customers when choosing a low-temperature constant temperature bath. Only when the temperature and volume are determined, can we choose a suitable product for customers based on their needs.

Most low-temperature constant temperature bath products on the market now use LCD screen control panels with digital display, simple settings, easy operation, temperature calibration, alarm signal display and other functions. The cold liquid in the tank can be drawn out, and the experimental container outside the cooling machine can be cooled. Touch the soft key to quickly set the temperature, making it easy to operate. Upper window LED digital temperature measurement value; The lower window LED displays the temperature setting value. The microcomputer corrects temperature measurement deviation and has an over temperature alarm system. These are all factors considered when selecting, and most products from Hengliu can meet the needs of customers.

4、 Environmental requirements

The constant temperature bath should be placed on a sturdy workbench; No vibration and no harmful gases; The room temperature should be relatively stable and not fluctuate rapidly, which may affect the accuracy of temperature control; The room temperature should be around 25 ℃ and not exceed 30 ℃ (especially for constant temperature baths at -40 ℃, -65 ℃, and -80 ℃). Excessive room temperature can affect compressor heat dissipation, reduce refrigeration efficiency, and easily cause malfunctions; If you feel that the cooling rate of the constant temperature bath slows down after working for a period of time, you should remove the plastic mesh plate of the constant temperature bath and clean the dust on the compressor and heat dissipation plate.

5、 Precautions for use

1. Add liquid medium into the tank before use, and the liquid level of the medium should be about 30mm lower than the worktable; A low liquid level can damage the heater when powered on.

2. The selection of liquid medium in the tank should comply with the following principles:

① When the working temperature is between 5-85 ℃, water is generally used as the liquid medium;

② When the working temperature is between 85-95 ℃, a 15% glycerol aqueous solution can be used as the liquid medium; Oil should be used when approaching or reaching 100 ℃;

③ When the working temperature is below 5 ℃, alcohol or freezing liquid is generally used as the liquid medium;

3. After the cooling switch is turned off, the cooling switch should be turned on again with an interval of 15-25 minutes (depending on the ambient temperature);

4. Power supply: 220V 50Hz, the power supply should be greater than the total power of the instrument, and the power supply must have a good "grounding" device;

5. The instrument should be placed in a dry and ventilated area, with no obstacles within 300mm around the instrument;

6. When the working temperature of the constant temperature bath is low, attention should be paid not to enter the bath with hands to prevent frostbite;

7. After use, place all switches in the off state and cut off the power supply;

8. The instrument should be regularly cleaned to maintain the cleanliness of the workbench and operating panel;

9. Regularly observe the liquid level in the tank. When the liquid level is too low, liquid medium should be added in a timely manner.

e178146a-14a1-4f58-a316-f502da2b2eb9.jpg

Previous:Usage and precautions of Shanghai Yetuo constant temperature water bath     Next:The purpose and precautions of Shanghai Yetuo handheld centrifuge
Follow us
Mobile station
  • Mobile:19961895916
  • Tel:19961895916
  • WeChat Account:上海葉拓科技
  • Email:yetuo@www.jasonzy.cn
  • Address:C2-301, green window, No. 4, Lvdu Avenue
Copyright? 2025 Shanghai Yetuo Technology Co., Ltd  ICP備案號:滬ICP備20000740號-3 主站蜘蛛池模板: 男人边吃奶摸下激烈免费视频 | 欧美男同GV免费网站观看 | 免费观看作爱视频网站 | chinese7o丰满vies| 色婷婷精品久久二区二区蜜臀av | 中国丰满少妇人妻XXX性董鑫洁 | 亚洲日韩色在线影院性色 | 无码日韩做暖暖大全免费 | 国产一级一片射内视频 | 亚洲AV无码久久精品色欲 | 日本做暖暖影院免费视频大全 | 在线观看视频在线高清免费播放网站 | 日日AV色欲香天天综合网 | 色欲AⅤ蜜臀AV免费观看 | 观看亚洲色欲色欲色欲WWW | 91中国少妇被黑人xxxxx | 日本黄色生活片 | 别c我啊嗯国产av一毛片 | 亚洲AV最新天堂地址 | 色在线影院 | 无码少妇一区二区浪潮免费 | 国产精品久久久影院 | 91看片.| www在线免费观看视频 | 九九精品超级碰视频 | 国产三级国产精品国产普男人 | 日韩美国国产一级毛片 | 神马影院在线免费 | 日本真人边吃奶边做爽动态 | 一级黄色大片视频 | 男女日批免费视频 | 成人欧美一区二区三区小说 | a一级片在线观看 | 国产精品理人伦一区二区三区 | 91导航福利 | 成人无码h动漫在线网站免费 | 波多野结衣在线视频一区二区三区 | 男女videos | 日日骚av| 午夜三级a三级三点在线观看 | 激情美女一区 |